BAM Capacitor Power Voltage High
Codsiga iyo Heerarka:
Capacitor danab sare ayaa inta badan loo adeegsadaa nidaamka Awooda AC oo leh 50Hz si loo hagaajiyo qodobka awooda. Waxqabadku waxa uu noqonayaa GB 3083.2-89 《High danab shunt capacitor》iyo IEC60871-1987.
GB/T11024-2010 Heerka Qaranka 《Qiimay danab 1kV ama ka sareeya capacitors shunt ee nidaamyada korantada AC
JB/7112-2000 Heerarka Warshadaha Mashiinada 《Kaydhiyaha Shunt ee HV la isku daray
DL/T628-1997 Heerka Warshadaha Korantada "HV Shunt Capacitor Dalbashada Shuruudaha Farsamo ee La Isugu keenay"
Shuruudaha Isticmaalka:
1.Altitude: in ka yar 1000m; Heerkulka deegaanka: -40℃ ~ +40℃.
2.Ma jiro gariir farsamo oo rabshad leh, ma laha gaas iyo uumi waxyeelo leh, koronto la'aan, iyo walxaha qarxa, iyo boodhka qarxa oo meesha yaal.
3.Volka hawlgalka joogtada ah: 1.00 Un, muddada dheer max, In ka badan danab: less.1 Un.
4.Stable over-curent (ay ku jiraan harmonics current) in ka yar 1.3 In.
5.With danab taagan: inta u dhaxaysa terminal 2.15, danab wakhtiga lagu qiimeeyay 10 seconds, inta u dhaxaysa terminal iyo weel 42kV 10 seconds.
Tilmaamaha farsamada ee ugu muhiimsan:
Voltage 1.Rated: 6.3kV, 6.6kV, 6.6 / √3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11 / √3kV, fadlan tilmaamay in amarka haddii aad rabto in aad awood kale oo gaar ah.
Awoodda 2.Rated: 33 ~ 334kvar fadlan ku calaamadee amarka haddii aad rabto awoodda kale ee gaarka ah.
3.Capacity dulqaad: -5 ~ 15%.
4.Loss angel tangential value: film & papaer medium tg θ≦0.08%, film dhexdhexaad ah tg θ≦0.05%.
5.Withstand danab: waxay awoodi kartaa AC2.15 ama DC4.3 jeer lagu qiimeeyay danab u dhexeeya awoodda cirro, ugu dambeeya oo ku saabsan 10s oo aan jabin ama flash, BIL: 6kV (30kV), 10kV (42Kv).
6.Free dheecaanka: waxa uu leeyahay iska caabin ah gudaha,10min ka dib markii la gooyay sahayda korontada, danab hadhaaga hoos u dhigi doonaa 75V ka √2 Un.
7.Max. Hadda: si habsami leh ugu socda 1.3 wakhtiga danab lagu qiimeeyay, in ka badan danab, dulqaad togan iyo mowjadda iswaafajinta oo aan ka badnaan karin 1 min 24 saacadood kasta.
8.Max.Current: oo si habsami leh ugu socda 1.3 wakhtiga lagu qiimeeyay danab, in ka badan danab, dulqaadka togan iyo hirarka harmonic taas oo aan 1.43 wakhtiga lagu qiimeeyay hadda.
9.Standard: GB/T 112024.1-2001, IEC6087:1997.
KAYDAHA AWOODDA WAJIGA SARE
Qaabka BAM | Voltage lagu qiimeeyay (kV) | Soo-saarka la qiimeeyay (kVar) | Awoodda la qiimeeyay (uF) | Lagu qiimeeyay hadda gudaha(A) |
6.3-25-1W | 6.3 | 25 | 2.006 | 3.968 |
6.3-30-1W | 6.3 | 30 | 2.406 | 4.762 |
6.6/√3-25-1W | 6.6/√3 | 25 | 5.481 | 6.561 |
6.3/√3-30-1W | 6.6/√3 | 30 | 6.577 | 7.873 |
6.3/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
10.5-25-1W | 10.5 | 25 | 0.722 | 2.38 |
10.5-30-1W | 10.5 | 30 | 0.886 | 2.857 |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
11/√3-30-1W | 11/√3 | 30 | 2.368 | 4.724 |
11/√3-50-1W | 11/√3 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | afar iyo labaatan | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
11/√3-50-1W | 11/√3 | 50 | 3.95 | 7.87 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
6.6/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
12/√3-100-1W | 12/√3 | 100 | 6.63 | 14.4 |
12/√3-150-1W | 12/√3 | 150 | 9.95 | 21.7 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-300-1W | 12/√3 | 300 | 19.9 | 43.3 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12/√3-400-1W | 12/√3 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | afar iyo labaatan | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | labaatan iyo laba | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |