ZW20-12 dibadda HV vacuum circuit jabiyaha waa 3-waji AC 50Hz 12kV qalabka beddelka dibadda
♦ Habka rakibaadda: tiirka lagu dhejiyay;
♦ Nooca cirifka: tiir isku dhafan;
♦ Codsiga: substation 12kV dibadda, warshad koronto.
♦ Nooca hawlgalka: buug-gacmeed, koronto, kontorool fog.
Xaaladaha Deegaanka
♦ Joog:
♦ Heerkulka hawada: -40°C~ + 40 ° C; heerkulka maalinlaha ah ee isbeddelka
Xawaaraha dabaysha
♦ Heerka wasakhda ah: IV;
♦ Meelaha lagu rakibo: Ma jiro dab, halis qarax, daxal kiimikada daran ama gariir daran;
♦ Xoogga dhulgariirka:
Halbeegyada Farsamo ee ugu muhiimsan
MAYA | Shayga | Unug | Qiimaha | |
1 | danab lagu qiimeeyay | kV | 12 | |
2 | Inta jeer ee korontadu waxay u adkeysan kartaa danab (1 daqiiqo) | (qalalan) wejiga dhexmara, dhulka/jabka; | kV | 42/48 |
(qoyan) wejiga dhexdooda, dhulka | 34 | |||
3 | Hillaaca u adkeysanaya danab (interphase, dhul/jabi) | kV | 75/85 | |
4 | Hadda la qiimeeyay | A | 630,1250 | |
5 | Inta jeer ee la qiimeeyay | Hz | 50 | |
6 | La qiimeeyay hadda jebinta wareegga gaaban | kA | 20, 25 | |
7 | Qiimaha ugu sarreeya ee u adkaysiga hadda (ugu sarreeya) | kA | 50, 63 | |
8 | Lagu qiimeeyay waqti gaaban oo u adkaysan kara hadda | kA | 20, 25 | |
9 | Wareeg gaaban oo la qiimeeyay samaynta hadda | kA | 50, 63 | |
10 | Lagu qiimeeyay muddada wareegga gaaban | S | 4 | |
11 | Sida loo shaqeeyo | Waqtiyada | O-0.3S-CO-1 80S-CO | |
12 | Wareeg gaaban oo la qiimeeyay jabinta lambarka hadda jira | Waqtiyada | 30 | |
13 | Nolosha makaanikada | Waqtiyada | 10000 | |
14 | Voltage hawlgalka la qiimeeyay (waa la beddeli karaa) | IN | 220 | |
15 | Waqtiga furitaanka | ms | ≤80 | |
16 | Waqtiga xidhitaanka | ms | ≤120 | |
17 | Waqtiga jabinta buuxda | ms | ≤100 | |
18 | Fiilada la qiimeeyay ee jabinta hadda | A | 50 | |
19 | Darajo | E2~C2~M2(10000) | ||
20 | Wareeg gaaban oo la qiimeeyay jabinta lambarka hadda jira | Waqtiyada | 30 |
Sawirka Qaab-dhismeedka Guud iyo Cabirka Rakibaadda (cutub: mm)
Siyaabaha loo rakibo